Fully Automated Organ Segmentation in Male Pelvic CT Images
Anjali Balagopal, Samaneh Kazemifar, Dan Nguyen, Mu-Han Lin, Raquibul Hannan, Amir Owrangi, Steve Jiang
TL;DR
Low CT soft-tissue contrast and variation in pelvic organs make accurate segmentation challenging, though it matters for radiotherapy planning. The paper uses a fully automated 2D localization and 3D segmentation workflow for pelvic CT. It reports mean DSC values from 0.84 to 0.96 across prostate, bladder, rectum, and femoral heads.
Problem
Low CT soft-tissue contrast and variation in organ shape, size, and intensity make automated pelvic-organ segmentation challenging for radiotherapy planning.
Source: INTRODUCTION · pp. 1–2Method
A multi-channel 2D U-Net localizes organs before a 3D U-Net with ResNeXt blocks segments their volumes.
Source: INTRODUCTION · p. 3, Localization network · p. 4, Segmentation network · p. 5Results
Mean DSCs were 0.90 for prostate, 0.95 for bladder, 0.84 for rectum, 0.95 for left femoral head, and 0.96 for right femoral head.
Source: DISCUSSION · p. 11Takeaways & Limitations
The workflow requires only CT images as input and is described as adaptable to segmenting other organs.
Source: CONCLUSION · p. 14Manual segmentation is imperfect ground truth because of inter-observer variability; the authors plan to use multiple observers’ averaged contours in future work.
Source: DISCUSSION · p. 14
Abstract
from arXiv · showhide
Accurate segmentation of prostate and surrounding organs at risk is important for prostate cancer radiotherapy treatment planning. We present a fully automated workflow for male pelvic CT image segmentation using deep learning. The architecture consists of a 2D localization network followed by a 3D segmentation network for volumetric segmentation of prostate, bladder, rectum, and femoral heads. We used a multi-channel 2D U-Net followed by a 3D U-Net with encoding arm modified with aggregated residual networks, known as ResNeXt. The models were trained and tested on a pelvic CT image dataset comprising 136 patients. Test results show that 3D U-Net based segmentation achieves mean (SD) Dice coefficient values of 90 (2.0)% ,96 (3.0)%, 95 (1.3)%, 95 (1.5)%, and 84 (3.7)% for prostate, left femoral head, right femoral head, bladder, and rectum, respectively, using the proposed fully automated segmentation method.
INTRODUCTION
Pelvic CT organ segmentation is difficult because of low prostate contrast and substantial variation among patients, despite its importance for radiotherapy planning. The paper proposes a fully automated deep-learning workflow that localizes organs with a multi-channel 2D U-Net and segments them with a 3D U-Net using ResNeXt blocks.
INTRODUCTION
- Low prostate-to-background contrast and patient variation in organ shape, size, and intensity, together with diverse CT acquisition conditions, make automated pelvic-organ segmentation challenging.Variation includes contrast-agent effects, differing fields of view, and implanted fiducial markers or catheters.Source: INTRODUCTION · pp. 1–2
- Prior shape-model and machine-learning methods can rely on same-patient prior-treatment samples and hand-crafted features, while a gap remains between automated results and manual annotations.Source: INTRODUCTION · p. 2
- U-Net uses skip connections between feature maps at matching depths to preserve local features while propagating global features to higher-resolution layers.Source: INTRODUCTION · p. 2
- CT segmentation is desirable for radiotherapy planning because current workflows use CT for contouring and dose calculation, although MRI has better soft-tissue contrast for delineating boundaries.Source: INTRODUCTION · p. 2
- The paper presents a fully automated pelvic-CT multi-organ workflow combining 2D U-Net localization with 3D U-Net segmentation using ResNeXt blocks.The authors describe it as a deep-learning-only workflow and claim improved accuracy over existing methods.Source: INTRODUCTION · p. 3
METHODS
The workflow separates organ localization from delineation and automates detection before segmentation. It crops and downsizes CT volumes, then passes localized organ volumes to the final segmentation network.
METHODS
- Organ segmentation comprises localization of an organ’s whereabouts and delineation of its spatial extent and composition.Source: METHODS · p. 3
- Because only about 15% of pelvic CT slices contain prostate and localization errors can mislead segmentation, the workflow adds a 2D U-Net to detect organs automatically before segmentation.Source: METHODS · p. 3
Automation workflow
- The workflow crops the upper and lower 15% of images to reduce memory use; the cropping margin was determined for UT Southwestern patients and may be removed without affecting accuracy.Source: Automation workflow · p. 3
- The CT volume is downsized for speed and memory, localized organ volumes are extracted, and those volumes are passed to the final segmentation network.Source: Automation workflow · p. 3, Figure 1 · p. 4
Localization network
A five-channel 2D U-Net localizes organs, and a 3D U-Net with ResNeXt blocks performs volumetric segmentation. The 3D design is motivated by the shape information and slice continuity that 2D networks may miss.
Localization network
- The five-channel 2D U-Net assigns one channel to each organ and takes the corresponding CT image and supervised-training binary mask as channel inputs.It predicts five organ feature maps and is trained with a custom weighted Dice loss using Adam.Source: Localization network · p. 4, Figure 2 · p. 5
Segmentation network
- The 3D U-Net uses ResNeXt blocks in its encoding arm because 3D kernels can capture organ shape and surface across sequential slices, unlike 2D curves alone.Source: Segmentation network · p. 5, Figure 3 · p. 6
- Each ResNeXt block aggregates n paths of two 3×3×3 convolutions, concatenates their outputs, and combines the result with the block input before encoding-arm max pooling.Source: Segmentation network · p. 5
- The segmentation network receives localized organ volumes with fixed slice counts—32 for prostate and 64 for each organ at risk—and is trained with boundary-weighted Dice loss using Adam.Source: Segmentation network · p. 6
Loss functions
The paper uses the Dice similarity coefficient to measure agreement between segmentation regions. It also identifies DSC as a useful segmentation-network loss for addressing class imbalance.
Loss functions
- The Dice similarity coefficient measures agreement between two image regions and is widely used to evaluate medical-volume segmentation against ground truth.Source: Loss functions · p. 6
- DSC is useful as a segmentation-network loss because it efficiently addresses class imbalance.Source: Loss functions · p. 6
- The ground-truth and predicted foreground-voxel counts are the quantities denoted by the notation in the DSC definition.Source: Loss functions · p. 6
Organ weighted dice function for localization network
The localization network uses class-weighted Dice loss, while the segmentation network uses boundary-weighted Dice loss. These weighting schemes address organ class representation and boundary pixels, respectively.
Organ weighted dice function for localization network
- For localization, annotated pixels receive weights inversely proportional to their class sample counts, so organs contribute more equally to the Dice loss.The organ-specific weight vector is determined during training from the number of samples belonging to that organ.Source: Organ weighted dice function for… · p. 7
Boundary weighted dice function for segmentation network
- For segmentation, boundary-weighted Dice assigns greater importance to pixels nearer the organ boundary, increasing their contribution to the loss.The border weight matrix is determined during training.Source: Boundary weighted dice function for… · p. 7
EXPERIMENTS & RESULTS Patients Data
The dataset comprised pelvic CT scans from 136 prostate cancer patients, with target organs contoured by experienced radiation oncologists.
- The dataset included raw CT scans from 136 prostate cancer patients collected at the University of Texas Southwestern Medical Center.Source: EXPERIMENTS & RESULTS Patients Data · p. 7
- Images were acquired using a 16-slice CT scanner with a 512x512 matrix and 2 mm slice thickness.The reported voxel size was 1.17mm×1.17mm×2mm.Source: EXPERIMENTS & RESULTS Patients Data · p. 7
- Experienced radiation oncologists contoured the prostate, bladder, rectum, and femoral heads.Source: EXPERIMENTS & RESULTS Patients Data · p. 7
Training Data
Training used four-fold leave-one-out validation, with predictions from the four models averaged for test-set prediction. The 3D U-Net used ResNeXt encoding blocks and training choices intended to balance accuracy, speed, and overfitting control.
Training Data
- Four-fold leave-one-out cross-validation reserved one group for validation, and the four models’ predictions were averaged on the test set.Eighty percent of patient data were used for training and the remaining 20% for testing.Source: Training Data · p. 7, Figure 4 · p. 8
- ResNeXt blocks were placed along the 3D U-Net encoding path to gain accuracy through cardinality without making the network too deep or computationally infeasible.The stated hardware constraint was an NVIDIA Tesla K80 dual-GPU card.Source: Training strategies · p. 8
- The model settled on 3×3×3 convolution kernels after 5×5×5 kernels produced inaccurate edges and small contours; a 1e-2 learning rate with plateau-based decay gave the best validation Dice.Source: Training strategies · p. 8
- Early stopping and dropout addressed overfitting, batch normalization was added for stability, and learning rate was decayed when validation loss plateaued.Source: Training strategies · p. 8
- Deep-learning models were implemented in Keras and processed on an NVIDIA Tesla K80 dual-GPU card.Source: Training strategies · p. 8
Results
The paper reports averaged-model test metrics and cross-validation results, alongside visual examples comparing predicted segmentations with ground truth. The averaged prostate model’s reported Dice values ranged from 85.9% to 93%.
Results
- Predicted segmentations closely resemble manual segmentations in the shown femoral-head, prostate, bladder, and rectum examples, including prostate base, middle, and apex slices.Figures 5 and 6 show organ examples, while Figure 7 shows prostate slices from base to apex.Source: Results · p. 9, Figure 5 · p. 9, Figure 6 · p. 9
- The averaged prostate model’s maximum DSC was 93% and minimum DSC was 85.9%.Figure 8 plots prostate DSC values for the four cross-validation models and the final averaged model.Source: Results · p. 10, Figure 8 · p. 10
- Cross-validation results for bladder, prostate, and rectum are summarized in Table 1, and Figure 9 shows Dice-coefficient distributions for all segmented organs.Source: Results · p. 10, Table 1 · p. 10, Figure 9 · p. 10
- The final test evaluation averaged predictions from four cross-validation models and reported average DSC, average surface distance, and average Hausdorff distance for DSC loss, plus average DSC for BCE loss.Table 2 also reports significance tests for the improvement when using weighted DSC loss.Source: Results · p. 11, Table 2 · p. 11
DISCUSSION
The discussion reports organ-wise segmentation accuracy and workflow timing, compares U-Net variants, and notes limitations in the manual reference. It also qualifies the rectum results and the cross-study comparison.
DISCUSSION
- Mean DSCs were 0.90 for prostate, 0.95 for bladder, 0.84 for rectum, 0.95 for the left femoral head, and 0.96 for the right femoral head.After training, test-set prediction took a few seconds; the full workflow took a few minutes per patient.Source: DISCUSSION · p. 11
- Rectum DSC was 0.84 with large variation, likely reflecting patient variation in organ size and shape; rectal-balloon cases were predicted well.The authors also suggest that reliance on MRI for many manual rectum segmentations may help explain the suboptimal results.Source: DISCUSSION · p. 11, Figure 10 · p. 12
- Direct comparison with published methods was not possible, although Table 3 compares reported DSC and surface-distance metrics.The surface measures are average surface distance and average Hausdorff distance.Source: Table 3 · p. 12, DISCUSSION · p. 12
- 90.2% cross-validation balanced accuracy for prostate and the lowest computation time marked the proposed 3D network as best among the tested U-Net variants.The architectures used the same patient dataset but were individually fine-tuned with different layer counts, depths, and dropout rates.Source: Table 4 · p. 13, DISCUSSION · p. 13
- All tested networks performed poorly without boundary-weighted Dice loss; Figure 11 contrasts predictions from weighted and normal Dice loss.The figure shows weighted-loss predictions in blue, normal-loss predictions in green, and ground truth in red.Source: Figure 11 · p. 13, DISCUSSION · p. 13
- Manual segmentation is an imperfect ground truth because of inter-observer variability; the authors propose averaging multiple observers' contours in future work.They also propose an ensemble network to combine organ segmentations without overlap.Source: DISCUSSION · p. 14
CONCLUSION
The conclusion presents a CT-only 2D–3D hybrid network for automated segmentation of prostate and organs at risk. It reports superior DSC performance relative to state-of-the-art methods, including the authors' 2D model.
CONCLUSION
- The hybrid network uses CT images as its only input and requires no manual intervention for segmentation.The authors state that the workflow could be adapted to segment other organs.Source: CONCLUSION · p. 14
- The network is reported to handle irregular prostates and rectums and achieve higher DSC than state-of-the-art methods, including the authors' 2D model.Source: CONCLUSION · p. 14
- The authors state that the workflow could be adapted for segmentation of other organs.Source: CONCLUSION · p. 14
Appendix A. Details on the 5 channel 2D U-Net architectures used for organ localization
The supplied appendix passages contain fragments naming convolution and max-pooling operations, alongside labels for architecture details and a prostate learning curve.
Appendix A. Details on the 5 channel 2D U-Net architectures used for organ localization
- A passage labels an appendix section as details on modified 3D U-Net architectures for organ segmentation.Source: Appendix A · p. 18
- The listed architecture fragments include four Max Pooling labels.Source: Appendix A · p. 19
- Other fragments list Conv labels 8 and 1, and name a learning curve for a single prostate validation set.Source: Appendix A · p. 20