Source-linked AI summary

Predicting optical coherence tomography-derived diabetic macular edema grades from fundus photographs using deep learning

Avinash Varadarajan, Pinal Bavishi, Paisan Raumviboonsuk, Peranut Chotcomwongse, Subhashini Venugopalan, Arunachalam Narayanaswamy, Jorge Cuadros, Kuniyoshi Kanai, George Bresnick, Mongkol Tadarati, Sukhum Silpa-archa, Jirawut Limwattanayingyong, Variya Nganthavee, Joe Ledsam, Pearse A Keane, Greg S Corrado, Lily Peng, Dale R Webster

arXiv:1810.10342v4cs.CVcs.LGstat.ML

TL;DR

Detecting ci-DME remains challenging, and this study evaluates deep learning with fundus photographs for predicting it. The model performed significantly better than retinal specialists across two different datasets, supporting fundus photographs as a lower-cost, more widely available means of identifying ci-DME.

  • Problem

    Detection of ci-DME remains a challenge.

    Source: Introduction · p. 3
  • Method

    The study trained a deep learning model to identify ci-DME from fundus photographs.

    Source: Discussion · p. 11
  • Results

    The model performed significantly better than retinal specialists for detecting ci-DME from fundus images in two very different datasets.

    Source: Discussion · p. 7
  • Takeaways & Limitations

    The study demonstrates that deep learning can identify ci-DME from cheaper, more widely available fundus photographs with accuracy exceeding manual grading using expert-derived rules.

    Source: Discussion · p. 11

    Future studies should include other geographic populations and OCT devices from other manufacturers.

    Source: Discussion · p. 11

Abstract

from arXiv · show

Diabetic eye disease is one of the fastest growing causes of preventable blindness. With the advent of anti-VEGF (vascular endothelial growth factor) therapies, it has become increasingly important to detect center-involved diabetic macular edema (ci-DME). However, center-involved diabetic macular edema is diagnosed using optical coherence tomography (OCT), which is not generally available at screening sites because of cost and workflow constraints. Instead, screening programs rely on the detection of hard exudates in color fundus photographs as a proxy for DME, often resulting in high false positive or false negative calls. To improve the accuracy of DME screening, we trained a deep learning model to use color fundus photographs to predict ci-DME. Our model had an ROC-AUC of 0.89 (95% CI: 0.87-0.91), which corresponds to a sensitivity of 85% at a specificity of 80%. In comparison, three retinal specialists had similar sensitivities (82-85%), but only half the specificity (45-50%, p<0.001 for each comparison with model). The positive predictive value (PPV) of the model was 61% (95% CI: 56-66%), approximately double the 36-38% by the retinal specialists. In addition to predicting ci-DME, our model was able to detect the presence of intraretinal fluid with an AUC of 0.81 (95% CI: 0.81-0.86) and subretinal fluid with an AUC of 0.88 (95% CI: 0.85-0.91). The ability of deep learning algorithms to make clinically relevant predictions that generally require sophisticated 3D-imaging equipment from simple 2D images has broad relevance to many other applications in medical imaging.

Introduction

Center-involved diabetic macular edema (ci-DME) is difficult to detect reliably from fundus photographs, while OCT-based diagnosis is costly and logistically difficult to deploy widely. The study hypothesizes that deep learning can predict OCT-derived DME grades directly from monoscopic fundus photographs.

Introduction

  • OCT is used to assess macular thickening for DME treatment eligibility, but adding OCT to screening is costly and logistically difficult to implement widely.Most clinical guidelines recommend annual screening for people with diabetes.Source: Introduction · p. 3
  • Hard exudates within one optic disc diameter of the macular center serve as a proxy for ci-DME, but studies report poor positive predictive value and sensitivity; only 42% of patients with hard exudates had DME on OCT.Source: Introduction · pp. 3–4
  • Deep learning has been applied to retinal-image tasks, and the authors hypothesized it could predict OCT-derived DME grades using monoscopic fundus photographs.The study frames this as a way to address unreliable ci-DME detection from fundus photographs alone.Source: Introduction · p. 4

Results

This section describes the labeling and training of a fundus-photo model to predict OCT-derived ci-DME and fluid, and reports its performance relative to retinal specialists. It also discusses performance across datasets, limits on generalization, borderline errors, fluid detection, and fovea-focused model explanations.

Results

  • 85% sensitivity at 80% specificity for ci-DME exceeded specialists’ 82-85% sensitivity at 45-50% specificity; at matched specificity, sensitivity was 96% versus 82-85%.At the same sensitivity, the model also had 30-35% higher absolute specificity than manual grading (p<0.001 for each specialist comparison).Source: Results · p. 5
  • AUC was 0.81 (95% CI: 0.81-0.86) for intraretinal fluid and 0.88 (95% CI: 0.85-0.91) for subretinal fluid.Source: Results · pp. 5–6
  • Absolute performance across the primary and secondary validation datasets is not directly comparable, especially for PPV, because ci-DME definitions and prevalence differed.The secondary dataset had 7.8% ci-DME cases versus 27.2% in the primary validation set.Source: Results · p. 6
  • Model AUC increased with larger training sets, suggesting accuracy may continue to improve with datasets larger than this study’s.Source: Results · p. 7
  • A 0.25 optic-disc-diameter crop around the fovea yielded AUC 0.75, while a 1.0-diameter foveal crop exceeded 0.85 and was comparable to full-fundus performance; optic-disc crops required 2.5 diameters of context.Source: Results · p. 7

Discussion

  • 88% of EyePACS-DME and 77% of Thailand moderate non-proliferative DR patients urgently referred by hard-exudate criteria lacked ci-DME.These would have been unnecessary urgent referrals under the hard-exudate-based criterion.Source: Discussion · p. 9
  • The model’s false positives and false negatives were more often borderline cases than retina specialists’ errors, including 17% of false negatives with thickness below 275 microns.The passage also reports false positives with thickness above 225 microns, but does not provide their proportion.Source: Discussion · p. 9
  • The model appears able to detect intraretinal and subretinal fluid, pathologies that merit closer monitoring and possibly treatment and that doctors cannot accurately identify from fundus images.The authors describe this fluid-detection capability as novel.Source: Discussion · p. 9
  • 35% was the model’s secondary-dataset PPV, down from 61% on the primary dataset; graders’ PPV fell from 37% to 18%, while sensitivity fell from 85% to 57% for the model and 84% to 55% for graders.The authors report that model performance was lower on the secondary dataset, but graders’ performance declined proportionally as well.Source: Discussion · p. 9
  • 96% was the model’s secondary-dataset NPV, up from 93% on the primary dataset; graders’ NPV rose from 88% to 95%, while specificity rose from 80% to 91% for the model and 47% to 79% for graders.The authors say these results reflect inherent dataset differences but still support better model performance than graders on both datasets.Source: Discussion · p. 10
  • Cropping experiments and the explanation technique indicated that the region around the fovea is more relevant than the optic-disc region for predicting DME from fundus images.The discussion presents these analyses as groundwork for understanding how the model makes predictions.Source: Discussion · pp. 10–11
  • The study demonstrates that deep learning can identify ci-DME from inexpensive, widely available fundus photographs with accuracy exceeding manual grading using expert-derived rules.Secondary-dataset performance was lower, confidence intervals were wide, and ci-DME criteria differed between datasets; PPV and NPV apply to populations with a similar severity distribution, and further validation across settings is needed. The model does not evaluate cases without central involvement that meet older treatment criteria.Source: Discussion · pp. 10–11

Measurement and assessment of OCT scans

  • Intraretinal fluid was defined by a hypo-reflective cystoid space within 500 μm of the foveal center, and subretinal fluid by a hypo-reflective space between retina and retinal pigment epithelium there.Two experienced medical doctors assessed OCT measurements and fluid presence under retinal-specialist supervision; a specialist reviewed a random 5% of patients.Source: Measurement and assessment of OCT scans · p. 14
  • ci-DME was defined as center point thickness >= 250 μm excluding the retinal pigment epithelium; EyePACS-DME used a machine-adjusted 300 μm central subfield thickness cutoff.Intraretinal and subretinal fluid labels were unavailable for EyePACS-DME.Source: Measurement and assessment of OCT scans · pp. 14–15
  • The model was trained to predict ci-DME, intraretinal fluid, and subretinal fluid from fundus photographs, without seeing OCT images during training or validation.The model output a confidence value for each prediction.Source: Measurement and assessment of OCT scans · p. 15

Evaluating the algorithm

The algorithm was evaluated using ROC-based measures and statistical comparisons, while separate experiments tested which fundus regions inform its predictions.

Evaluating the algorithm

  • The model was evaluated with ROC curves and AUC, specialist operating points, and additional thickness thresholds; metrics were also assessed at an operating point matching specialists’ specificity.The reported metrics included sensitivity, specificity, PPV, NPV, accuracy, and Cohen’s kappa.Source: Evaluating the algorithm · p. 16

Statistical Analysis

  • Statistical significance was assessed with 2,000 bootstrap resamples for 95% confidence intervals and 2,000 random permutations for comparisons.Bootstrap confidence intervals used the 2.5th and 97.5th percentiles of the resampled metric distribution.Source: Statistical Analysis · p. 16

Model Explanation

  • To test which image regions inform DME predictions, models were evaluated on progressively larger fovea-centered regions, with the rest of each image blacked out.The fovea and optic disc were manually marked, and region size was varied by optic-disc diameters.Source: Model Explanation · pp. 16–17

Data availability

Sharing of study data is restricted and requires ethical approval.

Data availability

  • Study data may be shared with qualified researchers following ethical approvals from Rajavithi Hospital.The authors state that restrictions apply to sharing the patient data supporting the findings.Source: Data availability · p. 17

Code availability

The models used standard machine-learning libraries and TensorFlow scripts, with custom code supporting infrastructure-specific data handling and parallelization.

Code availability

  • Models were developed and deployed with standard libraries and TensorFlow; custom infrastructure-specific code mainly handled data input/output and parallelization across computers.Source: Code availability · p. 18

Competing interests

The authors are employees of Google. The supplied material also describes the model’s clinical-validation comparisons and performance analyses.

  • The authors are employees of Google.Source: Competing interests · p. 18
  • The model and retinal specialists were compared on the primary validation set using OCT-defined ci-DME at a 250 μm center-point threshold.Source: Figure 2 · p. 21
  • 85% sensitivity at 80% specificity was the model’s ci-DME operating point on the primary clinical validation set.Source: Table 2 · p. 22
  • Model performance increased with training-data size across predictions of ci-DME, subretinal fluid, and intraretinal fluid.Source: Figure 3 · p. 23
  • The secondary validation compared the model with EyePACS graders using an OCT central-subfield threshold of 300 μm.Source: Figure 4 · p. 24
  • The crop analysis compares AUC across circular image regions centered on the fovea or optic disc, with radii from 0.05 to 2.5 disc diameters.Source: Figure 5 · p. 25

C. CPT>=320 μm

Supplementary analyses examine alternative OCT thresholds, error thickness distributions, and the evaluation set and training details.

C. CPT>=320 μm

  • OCT center-point thickness cutoffs of 280, 300, and 320 μm were used in supplementary ci-DME evaluations.Source: Figure S2 · p. 30
  • False-positive and false-negative center-point thickness distributions were compared for the model and specialists at an operating point matching specialist sensitivity.Source: Figure S3 · p. 31
  • The supplementary materials also identify the training data augmentation and model hyperparameters and compare the Thailand and EyePACS-DME datasets.Source: Figure S4 · p. 32, Table S2 · p. 33
  • Table S1 reports performance metrics on 948 images all three retinal specialists deemed gradable, with the model operating point matched to specialist sensitivity.Source: Table S1 · p. 33
Loading 1810.10342v4…