Vertical Assessment of RF-EMF Exposure in a Building Adjacent to a Multi-Operator Shared Base Station

Ricardo Q. de F. H. Silva, Marcio E. C. Rodrigues, Fred S. R. Pinheiro, Gutembergue S. da Silva, Halysson B. Mendonça, Vicente A. de Sousa Jr

arXiv:2609.12783v1cs.NI

TL;DR

Prior building studies often lacked floor-specific estimates of worst-case exposure using base-station data. This paper extends a proposed approach through vertical measurements in a critical shared-site scenario. The 10th floor had a peak of 31.86 V/m, 23.95 times the street-level peak.

  • Problem

    Earlier multi-building assessments used BS technical data to identify buildings in antenna-emission zones, but not to estimate which floors could face worst-case exposure.

    Source: §I · p. 1
  • Method

    The study reapplied the proposed approach and measured electric-field exposure vertically across a building directly exposed to emissions from a multi-operator site.

    Source: §I · p. 1, §V · p. 4
  • Results

    31.86 V/m was the peak on the 10th floor, 23.95 times the peak recorded at street level.

    Source: §IV · p. 4
  • Takeaways & Limitations

    The findings support considering BS antenna configuration in exposure assessments and updating BS parameter databases with reliable information.

    Source: §V · p. 5

    Uncertain antenna installation and tilt parameters, along with broadband measurements that cannot isolate operators or radio technologies, constrain interpretation of the floor discrepancy.

    Source: §IV · p. 4

Abstract

from arXiv · show

This paper extends a previously published proposed approach for estimating worst-case exposure scenarios in buildings using publicly available Base Station (BS) parameters, applying it to a critical case involving a multi-operator shared site. Radiofrequency Electromagnetic Fields (RF-EMF) exposure was assessed on every floor of a 20-story building facing the site, revealing significantly higher levels near the center of the antennas' estimated vertical zone of interest, with a peak of 31.86 V/m, 23.95 times higher than the street-level peak value. However, due to uncertainties in the input parameters, measurements across all locations within the zone of interest are required to accurately identify the floor of maximum exposure. The results demonstrate the usefulness of the proposed estimation approach and highlight the need for improved methods that consider BS antenna configurations and current technical information to ensure accurate assessments of exposure to RF-EMF.

I. INTRODUCTION

Prior building exposure studies either relied on modeling or measurements, while available technical data were rarely used to estimate floor-specific worst-case exposure. This study extends a publicly-data-based approach with full-building measurements in a high-exposure scenario.

I. INTRODUCTION

  • Prior work on building exposure included scenario modeling, and in-situ measurement campaigns –.The studies used different approaches to characterize or predict exposure in buildings.Source: §I · p. 1
  • Earlier multi-building studies used antenna data to identify exposed buildings, but did not estimate which floors might face worst-case exposure.Other studies were limited to single buildings with exact antenna and installation information,.Source: §I · p. 1
  • The proposed approach uses publicly available BS configuration and location data to select exposed buildings and estimate floors likely to have worst-case exposure.In 2024, measurements in four of Natal’s 22 target buildings reached average electric field strengths of 13.14 V/m and peaks of 22.79 V/m.Source: §I · p. 1
  • This study reapplies the approach in 2025 and adds continuous vertical measurements across all floors of a directly exposed building.The campaign provides additional empirical validation and characterizes exposure in a high-exposure scenario.Source: §I · p. 1

II. EVALUATED SCENARIO

The study assessed a building across the street from a shared site with two base stations, selected for its proximity and nearby telecommunications installations. The estimated vertical emissions centered on the 11th floor.

II. EVALUATED SCENARIO

  • The target building was selected as the most critical of 34 buildings because of its proximity and nearby telecommunications installations.It is directly across the street from a shared site with two BSs.Source: §II · p. 2
  • The assessment used geodesic distance, horizontal zone-of-interest diagrams, and ANATEL Mosaico data to identify directed emissions and potential transmitter power.Table I provides information about the target BSs.Source: §II · p. 2, Table I · p. 2
  • The -2° and 0° emissions from the 120°-azimuth antennas centered on the 11th floor, which also lay at the center of the horizontal zone of interest.Figure 1 depicts the horizontal and vertical zones and the 11th floor relative to the antennas.Source: §II · p. 2

III. MEASUREMENT PROCEDURE

Measurements covered every accessible building level, followed by longer measurements on the three floors with the highest initial field levels. The procedure also compared results with public-exposure limits and evaluated exposure ratios.

III. MEASUREMENT PROCEDURE

  • One-minute time-averaged measurements covered all levels from an accessible façade; 30-minute measurements followed on the three floors with the highest field levels.The building’s technical area allowed measurements without entering apartments.Source: §III · p. 2
  • A broadband NBM-520 meter and EF 0691 probe measured RMS electric-field intensity from 100 kHz to 6 GHz.The probe was set 1.7 m high and at least 2 m from people and reflective or absorptive surfaces; phones remained in airplane mode.Source: §III · p. 2
  • The study used a 27.70 V/m limit for broadband assessment and compared results with the 38.35 V/m most restrictive limit for target-BS bands.The 27.70 V/m limit corresponds to Natal broadcast services at 88–108 MHz; the 38.35 V/m limit corresponds to the 778 MHz LTE band.Source: §III · p. 3
  • Post-processing evaluated the Exposure Ratio using measured electric field and the public-exposure reference limit.Equation 1 defines Erms as measured RMS electric field in V/m and Elim as the regulatory public-exposure limit.Source: §III · p. 3

IV. RESULTS

The 10th floor had the highest measured electric-field values, with a 31.86 V/m peak, while the analysis anticipated the floors with the highest values despite a discrepancy in the estimated center floor.

  • In the one-minute campaign, the 10th floor had the highest average electric-field intensity at 17.16 V/m and the highest peak at 28.47 V/m.Source: Table V · p. 3, §IV · p. 4
  • The 30-minute campaign produced higher average and peak electric-field values than the first campaign on floors 9–11; the 10th floor averaged 17.34 V/m and peaked at 31.86 V/m.Source: §IV · p. 4, Table VI · p. 4
  • The reported electric-field strength was 31.86 V/m, 23.95 times higher than the peak value recorded at street level.Source: §IV · p. 4
  • Some floors showed unexpected value patterns, possibly because short one-minute measurements were more sensitive to changes from nearby services such as Wi-Fi.Source: §IV · p. 4
  • Despite a discrepancy between the estimated zone-of-interest center floor and the measured floor, the analysis anticipated the floors with the highest values, which exceeded ground-level exposure.Source: §IV · p. 4
  • The discrepancy may reflect uncertain antenna tilt information, while broadband measurements cannot isolate contributions by operator or radio access technology.Source: §IV · p. 4

V. CONCLUSIONS

The case study assessed every floor of a building in a critical multi-operator RF-emission scenario, finding higher field intensities nearer the antenna HPBW center. The results underscore the need for reliable, updated BS parameters and further work on exposure assessment.

V. CONCLUSIONS

  • The study assessed RF-EMF exposure on every floor of a building in a critical scenario near telecommunications infrastructure operated by multiple operators.Source: §V · p. 4
  • Average and peak electric field intensity rose significantly as the measurement floor approached the antenna HPBW center.The study calls for methods that consider BS antenna configuration when assessing RF-EMF exposure.Source: §V · p. 5
  • A discrepancy between the target floor and the floor with the highest exposure underscores the importance of reliable, continuously updated BS parameter databases for accurate and efficient measurements.Source: §V · p. 5
  • Future work will use narrowband equipment to examine each technology’s contribution and extend vertical measurements, including apartment interiors when access is needed.Source: §V · p. 5
  • The authors plan to obtain exact antenna models and configurations from operators to improve estimates and develop a predictive model incorporating frequency, antenna configuration, and distance.Source: §V · p. 5
  • Future measurements will relate field intensity to channel conditions, network configuration, and traffic load, including dense co-channel deployments with simultaneous transmissions.Source: §V · p. 5