Manual SYNTAX scoring is time-consuming and variable, while prior automated angiography work has focused mainly on component tasks or binary disease discrimination rather than continuous score prediction. SynSeq predicts patient-level SYNTAX scores from multi-view angiography videos using targeted preprocessing, sample weighting, and linear target scaling. SynSeq achieved R2 0.62 versus 0.07 for MVL and −0.11 for DeepRV, and remained stable across three independent expert annotators.
Problem
Manual SYNTAX scoring is time-consuming and variable, while prior automated angiography work has focused mainly on component tasks or binary disease discrimination rather than continuous score prediction.
Source: §1 · p. 2Method
SynSeq predicts patient-level SYNTAX scores from multi-view angiography videos using targeted preprocessing, sample weighting, and linear target scaling.
Source: §1 · pp. 2–3, §2 · p. 3Results
Takeaways & Limitations
SynSeq demonstrates the potential of learning-based SYNTAX estimation to support more consistent and scalable cardiovascular treatment planning.
Source: §5 · p. 10External validation across institutions and imaging protocols is required to assess generalizability beyond the public CardioSyntax dataset.
Source: §5 · p. 10
Abstract
from arXiv · showhide
The SYNTAX score is an established tool for assessing coronary artery disease and guiding revascularization treatment decisions. However, its manual estimation from coronary angiography videos by clinical experts is time-consuming and subject to inter-reader variability. While machine learning has shown promise in automating this process, prior work has primarily focused on lesion detection, characterization, or binary disease classification, leaving direct SYNTAX score prediction relatively unexplored. We propose SynSeq, a video-based method for direct SYNTAX score prediction. It combines targeted preprocessing with a tailored training strategy using a zero-inflation-aware loss and linear target scaling. Evaluated on the public CardioSyntax dataset, SynSeq significantly outperforms previous state-of-the-art methods, improving $R^2$ by 0.55, reducing prediction bias by 93.1% and achieving more consistent performance across annotations from three independent expert graders. In addition, SynSeq achieves a weighted $F_1$-score of 0.80 for revascularization treatment recommendations, slightly below inter-expert agreement. These results demonstrate the potential of SynSeq to provide consistent, automated SYNTAX score assessment and reliable decision support for coronary revascularization planning.
1 Introduction
The SYNTAX score informs revascularization decisions, but manual estimation is time-consuming and variable, while prior automated work has rarely addressed direct continuous score prediction. SynSeq targets that gap with multi-view video prediction and tailored preprocessing and optimization.
1 Introduction
- Manual SYNTAX scoring is time-consuming and subject to inter-observer variability, limiting its feasibility in everyday practice.The score is used to grade lesion severity, complexity, and location and inform revascularization decisions.Source: §1 · pp. 1–2
- Prior automated angiography methods largely address component tasks or binary disease discrimination, leaving continuous SYNTAX prediction across complex cases comparatively unexplored.Most earlier methods use single frames, and the CardioSyntax baselines emphasize zero-versus-nonzero classification.Source: §1 · p. 2
- SynSeq directly optimizes continuous patient-level SYNTAX scores from multi-view coronary angiography videos using targeted preprocessing and a tailored strategy for skewed labels.The strategy combines sample weighting with linear rather than logarithmic target scaling to preserve granularity in high-severity cases.Source: §1 · pp. 2–3
- Separate left- and right-vessel branches each encode angiography sequences and predict a SYNTAX score and vessel status; inference sums their score predictions.The branches share an architecture but have separate weights.Source: Figure 1 · p. 3
- Evaluation on the full CardioSyntax dataset reports significantly improved performance over prior state-of-the-art methods and increased robustness across multiple expert annotations.The evaluation uses the full dataset and compares performance across expert annotations.Source: §1 · p. 3
2 Method
SynSeq predicts patient-level SYNTAX scores from multi-view angiography videos, processing left and right coronary trees separately. Its training strategy combines long-tailed score handling, disease classification, staged optimization, and angiography-specific preprocessing.
- SynSeq processes left and right coronary trees independently, averages per-video sub-score predictions, then sums nonnegative side scores into a patient-level prediction.Source: §2 · pp. 3–4
- Angiography-specific training augmentations mimic acquisition variation; each patient must have at least one labeled video per tree, and clips use temporal center cropping or repetition padding.Source: §2 · p. 4
- Training addresses zero-inflated, skewed scores with inverse-frequency sample weighting and linear [0, 1] target scaling in weighted MSE rather than logarithmic scaling.Source: §2 · p. 4
- A multi-task objective combines regression with sample-weighted binary cross-entropy for disease-presence classification, balanced by hyperparameter α.Source: §2 · pp. 4–5
- Each tree's backbone is pretrained per video, then frozen while the dual-head LSTM is trained, before joint fine-tuning; sub-scores are aggregated at inference.Source: §2 · p. 5
3 Experimental Setup
The experiments use CardioSyntax and compare SynSeq with established baselines under patient-wise evaluation. They assess regression, treatment-category classification, partition sensitivity, and the contribution of individual design components.
- 1,844 patients in CardioSyntax contribute 9,590 left-artery and 3,970 right-artery videos, with primary sub-scores and additional consensus labels for 60 patients.Source: §3 · p. 5
- SynSeq is compared with MVL, a single-view DeepRV linear-probing baseline, and a naive mean using a patient-wise split with 60 multi-expert patients held out for testing.The remaining data use five-fold cross-validation, and test performance is reported as mean ± standard deviation across folds.Source: §3 · pp. 5–6
- Regression is assessed with R2, MAE, and mean-error bias, while treatment recommendations use weighted F1 across low, intermediate, and high risk categories.Source: §3 · p. 6
- Performance sensitivity is tested with a second 80/20 SYNTAX-stratified split of the full cohort, while the 60-patient consensus test split is the default.Source: §3 · p. 6
- Ablations cumulatively remove sample weighting, linear target-space optimization, or domain-specific preprocessing to measure changes in R2, MAE, and bias.Source: §3 · p. 6
- The implementation uses a Kinetics-400-pretrained R3D-18 backbone and projected LSTM, with backbone pretraining, frozen-backbone LSTM training, and joint fine-tuning.Source: §3 · p. 6
4 Results
SynSeq outperforms baselines on expert-labeled score regression, improves revascularization risk-category predictions, and performs consistently across independent expert annotations. Ablations indicate that the proposed components contribute to performance.
4 Results
- R² was 0.62 for SynSeq versus 0.07 for MVL and −0.11 for DeepRV on Expert 1 test labels.Table 1 reports regression performance on the test set using Expert 1 labels.Source: Table 1 · p. 7, §4 · p. 7
- For diseased samples, SynSeq reached R² 0.54, bias −0.90, and MAE 8.24, versus MVL/DeepRV R² −0.14/−0.17, bias −10.47/−2.28, and MAE 11.90/14.09.Improvements were consistent across folds and significant for bias (p<0.001) and MAE (p<0.05).Source: §4 · p. 7
- Weighted F1 was 0.80 ± 0.04 for SynSeq versus 0.64 ± 0.05 for MVL; SynSeq misclassified 11/60 patients versus 17/60.Only 3 SynSeq errors crossed multiple decision thresholds in a way that would alter treatment strategy, versus 12 for MVL.Source: §4 · p. 7, Figure 2 · p. 8
- Across three experts, SynSeq’s R² stayed 0.60–0.62, near expert-pair agreement of 0.65–0.67 but below the 0.83 maximum.Figure 2(b) shows reduced error variability versus MVL, approaching variability between human experts.Source: §4 · pp. 7–8, Table 2 · p. 7
- Removing sample weighting, linear scaling, or preprocessing degraded performance; without zero-clamping, R² was 0.58 ± 0.07, bias −2.15 ± 1.23, and MAE 7.87 ± 1.17.Zero-clamping affected an average of 16.6 of 60 test samples per side across folds.Source: §4 · p. 8, Table 3 · p. 8
- After full training, the healthy-versus-diseased head reached macro F1 0.747 ± 0.047 and accuracy 0.783 ± 0.051, above MVL at 0.703 ± 0.020 and 0.743 ± 0.023.Source: §4 · p. 9
5 Discussion and Conclusion
SynSeq improves agreement with expert SYNTAX scores and remains stable across independent annotators; its performance depends on preprocessing, linear-space optimization, and long-tailed score handling. The authors note limits to direct comparison with prior results and call for external validation beyond CardioSyntax.
- SynSeq consistently reduces error and improves agreement over MVL, with stable performance across three annotators despite training on one expert's labels.The authors suggest this reflects alignment with angiographic patterns rather than overfitting to individual annotation styles.Source: §5 · p. 9
- CardioSyntax has no official split, so its reported results may estimate different quantities and are not directly comparable with SynSeq's evaluation.The original study used five-fold cross-validation without a separate held-out test set; the authors used a held-out cohort and multiple seeds.Source: §5 · p. 9
- The baseline comparison is limited because CathAI, DeepCoro, and Deep-CoroCLIP weights and training data are unavailable.The authors also report that natural-prevalence class imbalance affects model calibration and performance.Source: §5 · p. 9
- External validation across institutions and imaging protocols is still required to assess generalizability beyond CardioSyntax.Source: §5 · p. 10
- The authors identify domain-specific preprocessing, linear-space optimization, and explicit sample weighting as design choices supporting improved and stable prediction.They connect linear-space training to the additive structure of SYNTAX scores and sample weighting to reduced underestimation near clinical decision thresholds.Source: §5 · pp. 9–10
- SynSeq has the potential to support more consistent and scalable cardiovascular treatment planning.Source: §5 · p. 10