Source-linked AI summary
InfiMed2: A Generalist Medical Multimodal Foundation Model from Contextual Evidence and Stability-Aware Supervision
Guanghao Zhu, Zeyu Liu, Zhitian Hou, Pengkai Wang, Zhijie Sang, Shuo Cai, Yang Yu, Yuanyi Wang, Yanggan Gu, Congkai Xie, Jianmin Wu, Hongxia Yang
TL;DR
Medical multimodal training still faces data-design challenges across continued pretraining and post-training, including heterogeneous evidence and short-answer supervision. InfiMed2 uses stage-aware corpus construction and stability-aware response regeneration, and its models achieve strong mean accuracy across five medical multimodal benchmarks.
Problem
Medical sources vary in structure, granularity, and information density, while short VQA targets offer limited supervision for informative, answer-consistent explanations.
Source: §1 · pp. 1–2Method
InfiMed2 combines source-specific processing of a 55.68B-token corpus and stage-aware CPT with stability-guided response regeneration, correctness-constrained selection, and RLVR for the 4B model.
Source: §1 · p. 2Results
Across five medical multimodal benchmarks, InfiMed2-4B reaches 66.73% mean accuracy and surpasses the larger Qwen3.5-9B, while InfiMed2-27B reaches 73.72%, highest among evaluated open-weight models.
Source: §1 · p. 2Takeaways & Limitations
The results support coordinated data design across continued pretraining and post-training as a practical route to stronger medical multimodal capability.
Source: §6 · p. 10InfiMed2 is intended for research and is not approved for unverified clinical use.
Source: ETHICS STATEMENT · p. 10
Abstract
from arXiv · showhide
Recent medical multimodal models have benefited from larger corpora, broader modality coverage, and stronger reasoning-oriented training, yet effective data design across continued pretraining (CPT) and post-training remains challenging. Medical sources vary substantially in structure, granularity, and information density, and their utility shifts as training progresses from broad knowledge acquisition to late-stage consolidation. Meanwhile, post-training is often dominated by short-form visual question answering, providing limited supervision for informative and answer-consistent explanations. We introduce InfiMed2, a family of 4B and 27B generalist medical multimodal foundation models built around stage-aware data design. We curate a 55.68B-token corpus that combines broad clinical knowledge with context-rich biomedical visual evidence through source-specific processing. Our CPT pipeline first adapts the vision encoder, then builds broad medical knowledge, and finally transitions to an evidence-focused data mixture during learning-rate decay. For supervised fine-tuning (SFT), we regenerate visual question-answering responses using answer stability, answer-masked reconstruction, and correctness-constrained selection to produce more informative and answer-consistent supervision. The 4B model is further optimized with reinforcement learning with verifiable rewards (RLVR). Across five medical multimodal benchmarks, InfiMed2-4B achieves 66.73% mean accuracy after RLVR, surpassing the larger Qwen3.5-9B, while InfiMed2-27B reaches 73.72%, the highest among the evaluated open-weight models.
1 INTRODUCTION
InfiMed2 addresses data-design challenges in continued pretraining and post-training by coordinating source-specific curation, training stages, and stability-aware response supervision. Across five medical multimodal benchmarks, its 4B model surpasses a larger baseline and its 27B model leads evaluated open-weight models in mean accuracy.
1 INTRODUCTION
- CPT must reconcile medical sources with different structures, granularity, and information density, while their value shifts between broad knowledge acquisition and late-stage consolidation.Early updates benefit from diverse coverage, whereas the low-learning-rate regime is more sensitive to evidence quality and task relevance.Source: §1 · pp. 1–2
- Short medical VQA targets provide limited supervision for explanations, and teacher-generated responses may be weakly grounded, inconsistent with verified answers, or unreliable across examples.Post-training data therefore needs to improve explanatory content while accounting for stability and correctness.Source: §1 · p. 2
- InfiMed2's CPT uses a 55.68B-token corpus with source-specific processing and separates vision-encoder adaptation, broad medical knowledge acquisition, and evidence-focused learning-rate decay.The final decay stage uses a compact mixture enriched with high-quality medical evidence.Source: §1 · p. 2
- 66.73% mean accuracy for InfiMed2-4B surpasses the larger Qwen3.5-9B, while InfiMed2-27B reaches 73.72%, the highest among evaluated open-weight models.Both results are reported under a common evaluation protocol on five medical multimodal benchmarks.Source: §1 · p. 2
- Stability-aware regeneration guides response reconstruction, correctness-constrained selection, escalation to a stronger model, and filtering to produce informative supervision consistent with verified answers.The selected 4B model subsequently uses reinforcement learning with verifiable rewards.Source: §1 · p. 2
2 RELATED WORK
Prior medical multimodal work has broadened models, data, and reasoning supervision, while source-aware evidence curation and verification of synthetic explanations remain less systematically studied. InfiMed2 addresses these gaps across continued pretraining and post-training.
2.1 MEDICAL MULTIMODAL FOUNDATION MODELS
- Recent generalist medical multimodal systems broaden data, modalities, and reasoning supervision, but source-aware evidence curation and synthetic-explanation verification remain less systematically studied.InfiMed2 addresses these data-design problems across continued pretraining and post-training.Source: §2.1 · pp. 2–3
2.2 MULTIMODAL CONTINUED PRETRAINING AND MEDICAL DATA CURATION
- Biomedical figure collections can reduce literature evidence to isolated figure–caption pairs and remain vulnerable to extraction noise, while source diversity and stage-dependent data value are underexplored.PMC-InterCPT reconstructs associations among figures, captions, and related context; InfiMed2 combines complementary medical sources through source-aware processing.Source: §2.2 · p. 3
2.3 MEDICAL POST-TRAINING AND RELIABLE SYNTHETIC SUPERVISION
- Generated medical explanations may be weakly grounded or inconsistent with verified answers, motivating regeneration that combines reliability signals with reference-answer constraints.Self-consistency and predictive uncertainty are identified as useful reliability signals.Source: §2.3 · p. 3
3 DATA CURATION
InfiMed2 curates data around complementary medical sources and training stage, then filters and regenerates post-training examples to improve evidence quality, answer consistency, and visual balance.
3.1 CPT DATA CURATION
- The 55.68B-token CPT corpus combines medical e-books, biomedical literature, medical web documents, and general multimodal replay using source-specific processing.Its components are 29.78B, 9.63B, 11.27B, and 5B tokens, respectively.Source: §3.1 · p. 3
3.2 POST-TRAINING DATA CURATION
- Post-training curation sequentially filters invalid samples, regenerates informative VQA responses while preserving answer correctness, and forms a mixture by visual content.The curation addresses semantic inconsistencies, short-form answers, and imbalanced visual content.Source: §3.2 · p. 5
3.2.1 FINE-GRAINED QUALITY FILTERING
- A fine-grained annotation scheme assesses image–question alignment, information completeness, and logical validity; a trained evaluator removes samples with critical defects.The evaluator assigns three levels, with Score 0 marking a critical defect, Score 1 a limited non-fatal issue, and Score 2 a valid sample.Source: §3.2.1 · p. 5
3.2.2 STABILITY-AWARE RESPONSE REGENERATION
- 94.10% of 704,046 answer-masked reconstructions recover the reference answer, and the procedure exports 106,183 final examples.Stable samples undergo answer-masked reconstruction and correctness-constrained selection; intermediate-stability samples receive escalated regeneration, while samples with very low stability are discarded.Source: §3.2.2 · pp. 5–6
3.2.3 VISUAL-MODALITY-AWARE MIXTURE CONSTRUCTION
- Category-level sampling across 27 visual categories reduces domination by frequent modalities while preserving clinically relevant long-tail content.The resulting SFT mixture contains 296,725 examples and 241.85M tokens, including 106,183 stability-aware examples totaling 108.32M tokens.Source: §3.2.3 · p. 6
4 MODEL TRAINING
InfiMed2 trains through staged continued pretraining followed by supervised fine-tuning, with an additional RLVR stage for the 4B model.
4 MODEL TRAINING
- The 4B and 27B runs start from Qwen3.5-4B-Base and the instruction-tuned Qwen3.5-27B checkpoint, respectively, and both proceed through CPT and SFT.The 30B-CPT 4B variant additionally undergoes RLVR after SFT.Source: §4 · pp. 6–7
4.1 CONTINUED PRETRAINING
- CPT proceeds through vision-encoder adaptation, broad warmup–stable training, and learning-rate decay on a high-quality 2.50B-token mixture.The stages use a 1B-token image–caption subset and a 55.68B-token mixture before the final decay mixture.Source: §4 · p. 7, §4.1 · p. 7
4.2 SUPERVISED FINE-TUNING
- SFT trains all model components for five epochs on a 241.85M-token mixture combining general multimodal instructions, medical VQA, reasoning supervision, and stability-aware responses.The run starts from the post-decay checkpoint.Source: §4.2 · p. 7
4.3 REINFORCEMENT LEARNING WITH VERIFIABLE REWARDS
- RLVR uses answer accuracy and format compliance rewards, prioritizing prompts with 3–5 correct rollouts while downsampling near-unsolved and saturated examples.A smaller easy subset is retained to reduce forgetting after SFT.Source: §4.3 · p. 7
5 EXPERIMENTS
The experiments evaluate InfiMed2 against general-purpose and medical models under a common five-benchmark protocol, then test CPT checkpoint choice, RLVR, and response-target selection. Results show strong average performance alongside trade-offs across training stages and target formats.
5.1 EXPERIMENTAL SETUP
- Evaluation covers five benchmarks and reports each accuracy plus their unweighted mean, with models assessed on the same questions, prompts, and scoring procedure.The compared models include general-purpose and medical multimodal baselines, alongside SFT-only controls.Source: §5.1 · pp. 7–8
5.2 MAIN RESULTS
- 66.73% mean accuracy lets InfiMed2-4B outperform the larger Qwen3.5-9B by 2.02 points, while InfiMed2-27B reaches 73.72%, the highest among evaluated open-weight models.The comparison uses the paper’s common evaluation protocol across five medical multimodal benchmarks.Source: §5.2 · p. 8, Table 1 · p. 8
5.3.1 CPT CHECKPOINT SELECTION AND RLVR
- Under matched SFT, average performance peaks at 30B warmup–stable CPT tokens for 4B and 24B for 27B; RLVR improves all five benchmarks for the selected 4B checkpoint.The reported gains are largest on MedXpertQA-MM and PMC-VQA-clean; extending the 27B run improves some tasks but reduces others.Source: §5.3.1 · pp. 8–9, Table 2 · p. 8, Figure 2 · p. 9
5.3.2 STABILITY-AWARE RESPONSE REGENERATION
- With the same 4B checkpoint and 20k PMC-VQA examples, stability-aware response selection performs best on average, while answer-only targets remain stronger on direct-answer VQA.Generated explanations improve reasoning-oriented benchmarks, and stability-aware selection exceeds random response selection.Source: §5.3.2 · p. 9, Table 3 · p. 9
5.4 DISCUSSION
- Neither longer CPT nor more verbose supervision is uniformly beneficial; checkpoint choice should follow downstream capability profiles, and post-training should retain concise targets or adapt response format to the task.The discussion also identifies open-ended clinical communication and expert assessment of explanation quality as future evaluation areas.Source: §5.4 · p. 9
6 CONCLUSION
InfiMed2 combines coordinated data design across continued pretraining and post-training with source- and stage-specific curation. The 4B and 27B models achieve strong results among evaluated open-weight models, and the ablations support matching data construction to each training stage.
6 CONCLUSION
- InfiMed2 coordinates source-specific curation and stage-specific mixtures across continued pretraining and post-training to build 4B and 27B generalist medical multimodal models.The conclusion describes the approach as a practical route to stronger medical multimodal capability, supported by the ablations.Source: §6 · p. 10
AI USE STATEMENT
The statement describes AI assistance in literature search, code, drafting, formatting, and post-training data construction, with author review and responsibility. It also states research-use and release boundaries.
AI USE STATEMENT
- Generative AI assisted literature search, code development, early-draft polishing, formatting, and post-training data construction; authors reviewed and verified outputs and take responsibility.Source: AI USE STATEMENT · p. 10
ETHICS STATEMENT
- The study uses no new human-participant data or prospective clinical intervention; heterogeneous corpora may still contain errors, biases, or sensitive content, and the model is not approved for unverified clinical use.Source: ETHICS STATEMENT · p. 10
REPRODUCIBILITY STATEMENT
- Planned release covers trained models and selected data or metadata only where licenses and privacy conditions permit redistribution; restricted resources will instead have provenance, preprocessing descriptions, and reconstruction scripts.Source: REPRODUCIBILITY STATEMENT · p. 10
A ADDITIONAL DATA CURATION DETAILS
The appendix details source-specific curation and sampling for medical books, biomedical literature, web data, and stage-specific CPT mixtures. These procedures rebalance medical content and prepare evidence-rich data for training.
A.1 MEDICAL E-BOOK PROCESSING AND SAMPLING
- After rebalancing, the sampled book corpus contains 60,433 books and 22.41B text tokens, or 29.78B tokens including visual tokens.Clinical disciplines rise from approximately 55% to 75% of text tokens, while basic medicine falls from 21.3% to 9.2%.Source: §A.1 · p. 13
A.2 BIOMEDICAL SCIENTIFIC LITERATURE
- PMC-InterCPT links figures to explicitly referencing context, repairs incoherent records, filters for medical relevance and text quality, and excludes PMC-VQA test examples.Its final token budget allocates 45% to biomedical visual evidence, 30% to quantitative and tabular evidence, 20% to mechanism and structure evidence, and 5% to auxiliary evidence.Source: §A.2 · p. 13
A.3 MEDICAL WEB CURATION DIAGNOSTICS
- Web curation yields an 11.27B-token training corpus after retrieval, deduplication, quality filtering, image downloads, and format validation.The component diagnostics assess individual filters rather than the end-to-end quality of the resulting corpus.Source: §A.3 · pp. 13–14
A.4 STAGE-SPECIFIC CPT MIXTURES
- Vision-encoder adaptation uses a 1B-token PMC-InterCPT subset, while learning-rate decay uses a compact mixture emphasizing curated medical sources and retaining controlled general replay.The decay mixture totals 2.50B tokens.Source: §A.4 · p. 14, Table 4 · p. 14
B.1 POST-TRAINING QUALITY ASSESSMENT
This section describes sample-quality scoring, the supervised fine-tuning mixture, and stability-aware response regeneration. The regeneration pipeline filters candidate answers and retains long-form responses whose masked reconstructions preserve correctness.
B.1 POST-TRAINING QUALITY ASSESSMENT
- The quality evaluator uses three levels: Score 0 marks critical defects, Score 1 limited but non-fatal issues, and Score 2 valid samples without listed defects.The assessment protocol is provided in Table 5.Source: §B.1 · p. 14, Table 5 · p. 14
B.2 SUPERVISED FINE-TUNING MIXTURE COMPOSITION
- The final SFT mixture contains 296,725 effective training examples and 241.848M tokens.Vision and text contribute 120.459M and 121.389M tokens, respectively.Source: §B.2 · p. 15, Table 6 · p. 15
B.3 STABILITY-AWARE ROUTING AND RETENTION
- Of 176,948 questions, 106,183 examples enter SFT after candidate generation, correctness checks, selection, filtering, and cleaning.The selected supervision contributes 108.316M training tokens, including 45.382M visual tokens and 62.933M text tokens.Source: §B.3 · p. 15, Table 7 · p. 15
- Answer-masked reconstructions average 11.62 tokens versus 418.31 tokens for correct candidates, and 662,503 of 704,046 reconstructed answers remain correct (94.10%).The reconstruction checks whether a long response preserves the reference answer without replacing the informative long-form SFT target.Source: §B.3 · p. 15
C TRAINING AND IMPLEMENTATION DETAILS
The appendix specifies shared optimization choices, RLVR settings, and the sources used for medical reasoning. It emphasizes verifiable answer accuracy while retaining response-format compliance.
C TRAINING AND IMPLEMENTATION DETAILS
- CPT and SFT use AdamW with β1 = 0.9, β2 = 0.95, ϵ = 10−8, and gradient clipping at a maximum norm of 1.0.During warmup–stable CPT and learning-rate decay, weight decay is 0.1, excluding bias and RMSNorm parameters.Source: C TRAINING AND IMPLEMENTATION DETAILS · p. 15, Table 8 · p. 16
C.1.1 OPTIMIZATION SETTINGS
- RLVR combines format compliance and answer accuracy rewards at a 1:9 weight ratio, placing most optimization signal on verifiable correctness.Training runs for three epochs with learning rate 1×10−6, global batch size 128, and eight rollouts per prompt.Source: §C.1.1 · p. 16, Table 9 · p. 16
C.1.2 DATA COMPOSITION
- The RLVR resources combine image-grounded clinical questions with text-only medical reasoning, with train and test partitions reported for each source.Table 10 summarizes the resource composition.Source: §C.1.2 · p. 16, Table 10 · p. 16
D.1 BENCHMARK OVERVIEW
The appendix describes five medical multimodal benchmarks, a common inference and scoring protocol, and qualitative comparisons of model responses. The case studies highlight differences in evidence integration, statistical reasoning, explanation consistency, and diagram grounding.
D.1 BENCHMARK OVERVIEW
- MMMU-Medical-test, MMMU-Pro-Medical-10, MedXpertQA-MM, PMC-VQA-clean, and OmniMedVQA cover expert medical reasoning, visual questions, and diverse medical images.The benchmarks include Health and Medicine subsets, multi-step multimodal questions, and broad coverage across modalities and anatomical regions.Source: §D.1 · pp. 16–17
D.2 INFERENCE AND PROMPTING PROTOCOL
- All models use the same benchmark examples, prompts, generation limits, and answer extraction, with exact-match accuracy computed from the tagged option letter.OmniMedVQA uses a direct-answer prompt; the other named benchmarks use the reasoning prompt.Source: §D.2 · p. 17
D.3 QUALITATIVE CASE STUDIES
- The cases show RLVR responses integrating clinical and visual evidence, selecting risk ratio from observed attack rates, and aligning explanation mechanisms with answers; anatomical label grounding remains variant-dependent.In one diagram example, InfiMed2-27B maps the atrioventricular node to label C, while InfiMed2-4B describes the anatomy correctly but maps it to the wrong marker.Source: §D.3 · pp. 18–20